All steam boilers by output
Boiler type
|
SSS 160 |
SSS 260 |
SSS 360 |
SSS 460 |
SSS 560 |
2 x DG 560 |
3 x DG 560 |
4 x DG 560 |
Unit type
|
Single unit
|
Single unit
|
Single unit
|
Single unit
|
Single unit
|
Double unit
|
Triple unit
|
Quad unit
|
Steam boiling up to
|
160 kg/h
|
260 kg/h
|
360 kg/h |
460 kg/h |
560 kg/h |
1120 kg/h |
1680 kg/h |
2240 kg/h |
Thermal load up to
|
110 kW |
175 kW |
245 kW |
315 kW |
400 kW |
800 kW |
1200 kW |
1600 kW |
Thermal output up to
|
105 kW |
170 kW |
235 kW |
300 kW |
380 kW |
760 kW |
1140 kW |
1520 kW |
Max. operating pressure
|
13 bar (overpressure)
|
13 bar (overpressure)
|
13 bar (overpressure)
|
13 bar (overpressure)
|
13 bar (overpressure)
|
13 bar (overpressure)
|
13 bar (overpressure)
|
13 bar (overpressure)
|
Warming up time
|
8 Min.
|
8 Min.
|
8 Min.
|
8 Min.
|
8 Min.
|
8 Min.
|
8 Min.
|
8 Min.
|
Max. oil throughput
|
9,2 kg/h
|
14,6 kg/h |
20,5 kg/h |
26,5 kg/h |
32,6 kg/h |
65,2 kg/h |
97,8 kg/h |
130,4 kg/h |
Max. as throughput
|
10,6 m3/h |
17 m3/h |
23,7 m3/h |
30,5 m3/h |
37,7 m3/h |
75,4 m3/h |
113,0 m3/h |
150,7 m3/h |
Gas flow pressure min.
|
20 mbar
|
20 mbar |
20 mbar |
20 mbar
|
20 mbar
|
20 mbar
|
20 mbar
|
20 mbar
|
Gas connection
|
1"
|
1"
|
1"
|
1"
|
1"
|
1"
|
1"
|
1"
|
Exhaust mass flow
|
0,05 kg/s |
0,08 kg/s |
0,11 kg/s |
0,14 kg/s |
0,18 kg/s |
0,18 kg/s |
je 0,18 kg/s |
je 0,18 kg/s |
Exhaust stack D
|
150 mm
|
180 mm
|
180 mm
|
250 mm
|
300 mm
|
je 300 mm
|
je 300 mm
|
je 300 mm
|
Flue draft min.
|
0,15 mbar
|
0,15 mbar
|
0,15 mbar
|
0,15 mbar
|
0,15 mbar
|
je 0,15 mbar
|
je 0,15 mbar
|
je 0,15 mbar
|
El. connection
|
400 V / 50 Hz
|
400 V / 50 Hz
|
400 V / 50 Hz
|
400 V / 50 Hz
|
400 V / 50 Hz
|
400 V / 50 Hz
|
400 V / 50 Hz
|
400 V / 50 Hz
|
El. power consumption
|
1,5 kW
|
1,5 kW
|
1,5 kW
|
1,5 kW
|
1,5 kW
|
je 1,5 kW
|
je 1,5 kW
|
je 1,5 kW
|
Total weight
|
580 kg
|
680 kg
|
780 kg
|
1180 kg
|
1290 kg
|
je 1290 kg
|
je 1290 kg
|
je 1290 kg
|
Boiler height B
|
1580 mm
|
2080 mm |
2140 mm |
2140 mm |
2240 mm |
2240 mm |
2240 mm |
2240 mm |
Boiler width C
|
800 mm |
800 mm |
800 mm |
930 mm |
930 mm |
je 930 mm |
je 930 mm |
je 930 mm |
Boiler depth F
|
1380 mm |
1590 mm |
1590 mm |
1690 mm |
1690 mm |
je 1690 mm |
je 1690 mm |
je 1690 mm |
Installation height A
|
1250 mm |
1420 mm |
1590 mm |
1590 mm |
1590 mm |
1590 mm |
1590 mm |
1590 mm |
Installation width
|
690 mm |
800 mm |
800 mm |
930 mm |
930 mm |
930 mm |
930 mm |
930 mm |
Installation depth E
|
780 mm |
800 mm |
800 mm |
930 mm |
930 mm |
930 mm |
930 mm |
930 mm |
Exhaust stack G
|
850 mm |
1440 mm |
1440 mm |
1440 mm |
1440 mm |
1440 mm |
1440 mm |
1440 mm |
Request
With Jumag steam generator models there is one for every application. The following table contains all Jumag steam generators, sorted ascending by steam output.
The following output stages are available in four different build forms:

Do you still have questions?
Our sales team would be pleased to discuss your specific requirements with you:
+49 (0) 6203 955086-17